Trang chủ » blog » Vanquish 440 | 540: Detector Settings – Volume | Sensitivity

Vanquish 440 | 540: Detector Settings – Volume | Sensitivity

Detector Settings

Volume

The volume control changes the flashiness of aim signals.
Use the volume Minus and Plus buttons to adjust the volume Level. Each press will decrease/increase the volume by one degree .
Minelab Vanquish 440 | 540 Volume

The Volume adjustment buttons.
The volume alteration buttons. A low tone will sound when the maximum or minimum bulk floor is reached.

The volume Level indicator on the display shows the current estimate book Level. Each prevention represents two levels .
Minelab Vanquish 440 | 540 Volume Max

The Volume Level indicator showing maximum volume (levels 9 or 10)

Backlight

The bulk Level index showing maximal volume ( levels 9 or 10 ) The VANQUISH 540 has a red backlight for detecting in lowlight situations. The Backlight is turned off by default at each start-up to reduce battery pulmonary tuberculosis.
Press the Backlight button to turn the backlight on or off. The Backlight Indicator appears on the display when the backlight is on .
Minelab Vanquish 540 Backlight Button
The Backlight button   

Minelab Vanquish 540 Backlight Indicator

The Backlight indicator

Sensitivity

The VANQUISH Series detectors are highly medium and have adjustable sensitivity. Setting the right sensitivity level for individual detection conditions will maximize detection depth.
Always choose the highest stable sensitivity setting to ensure optimum performance.
The Sensitivity Level indicator on the display shows the current Sensitivity Level. Each bar represents one level.

Minelab Vanquish 440 | Sensitivity

The Sensitivity Level indicator (540 shown) showing maximum sensitivity (level 10)

To Adjust the Sensitivity Level

The Sensitivity Level indicator ( 540 shown ) showing utmost sensitivity ( flat 10 ) Hold the coil stationary, then use the Sensitivity Plus button to increase the sensitivity until false signals begin to occur .
Minelab Vanquish Sensitivity Adjustment

The Sensitivity adjustment buttons

  1. Reduce the sensitivity level by pressing the Sensitivity Minus button, just enough that the false signals disappear.
  2. Sweep the coil over a clear patch of ground, and reduce the Sensitivity Level further if any ground noise is encountered.

Excessive Noise

The Sensitivity allowance buttons sometimes, excessive noise is encountered whilst detect.
This can be caused by environmental electromagnetic interference ( EMI ) from sources such as exponent lines, fluid earphone towers, or early metallic detectors.
If noise is a problem, try the following steps in ordain until the make noise is eliminated.

  1. Move away from local sources of Electromagnetic Interference (EMI).
  2. Restart the detector, and wait for the automatic Noise Cancel process to complete.
  3. If restarting the detector does not eliminate the excessive noise, then try reducing the Sensitivity Level.

Automatic Noise Cancel

VANQUISH Series detectors have an automatic pistol Noise Cancel process that occurs every prison term the detector is powered on. It calibrates the detector so that excessive
noise is not experienced.
For best results, the gyrate should be held stationary good above the grind until Automatic Noise Cancel is arrant ( indicated by two bombastic dashes displayed on the Target ID Number field ) .

IRON BIAS

The Iron Bias feature is set to High by default, allowing the detector to correctly classify large or complex ferric targets, such as hoary nails or bottle crown caps, as ferric, which can be more easily rejected.
The VANQUISH 540 allows the Iron Bias degree to be set to Low. This allows the detector to better identify coins amongst dense ferric folderol .

Set Iron Bias to Low (540 only)

The VANQUISH 540 Iron Bias is returned to its default option setting each time the detector is powered on .

  1. Long-press the All‑Metal button for approximately 2 seconds.

    Minelab Vanquish 340: All-metal

         The All‑Metal button (long-press for Iron Bias)

  2. The Iron Bias Indicator will appear on the display to the left of the Target Identification Number to indicate that Iron Bias is set to Low.
    Minelab Vanquish Iron Bias Indicator

          The Iron Bias Indicator

  3. To return the Iron Bias setting to High, Long-press the All‑Metal button for approximately 2 seconds. When Iron Bias is set to High, The Iron Bias indicator is off, and no icon is displayed.
reference : https://leowiki.com
Category : Economy

Post navigation

Leave a Comment

Trả lời

Email của bạn sẽ không được hiển thị công khai.